Testonic Disinfectant Residue Test Kit – QAC Disinfectants – Titrimetric is designed for titrimetric determination of quaternary ammonium compounds (QAC) in disinfectant working solutions, process samples and post-disinfection control samples.
The drop / titration-count system provides rapid field determination within a 50–1000 ppm QAC range. It supports verification of applied or residual QAC levels in food processing, industrial hygiene, equipment sanitation and other QAC-based disinfection processes.
What Is It Used For?
In QAC-based disinfection processes, both the concentration of the applied disinfectant and the remaining active level at the selected process point may need to be verified.
The kit supports on-site titrimetric determination of QAC concentration during disinfectant preparation, application and process verification.
- QAC disinfectant working-solution control
- CIP / COP and equipment sanitation
- Food and beverage production lines
- Tanks, pipelines and filling equipment
- Industrial hygiene and surface disinfection
- Post-disinfection QAC residue verification
How Is the Titrimetric Result Calculated?
According to the product titration factor, each titration division corresponds to 50 ppm QAC.
| Titration Result | QAC Concentration |
|---|---|
| 1 division | 50 ppm |
| 2 divisions | 100 ppm |
| 5 divisions | 250 ppm |
| 10 divisions | 500 ppm |
| 20 divisions | 1000 ppm |
Which QAC Compounds Can Be Checked?
| QAC Compound | Abbreviation |
|---|---|
| Benzalkonium Chloride | BAC |
| Cetyltrimethylammonium Chloride | CTAC |
| Cetylpyridinium Chloride | CPC |
| Didecyl Dimethyl Ammonium Chloride | DDAC |
| Alkyl Dimethyl Benzyl Ammonium Chlorides | ADBAC |
| Octyl Decyl Dimethyl Ammonium Chloride | ODDAC |
| Dodecyltrimethylammonium Chloride | DTAC |
| Dodecyltrimethylammonium Bromide | DTAB |
Results are interpreted as a QAC-equivalent concentration according to the calibration of the test system.
Basic Technical Data
| Control parameter | Quaternary ammonium compounds (QAC) |
| Method | Titrimetric |
| Titration factor | 1 division = 50 ppm QAC |
| Measurement range | 50–1000 ppm QAC |
| Approximate result time | 5 minutes |
| Approximate test capacity | 50 tests |
| Storage temperature | 8–24 °C |
| Shelf life | 24 months unopened |
| After opening | Recommended for use within 12 months |
Which QAC Test Should I Choose?
| Control Requirement | Recommended Test | Result |
|---|---|---|
| Determine QAC disinfectant concentration | Disinfectant Residue Test Kit – QAC – Titrimetric | Titrimetric result from 50 to 1000 ppm |
| Check QAC / cationic detergent residue after rinsing | QAC / Cationic Detergent Residue Test Kit | Qualitative residue control by phase separation |
Frequently Asked Questions
Hygiene and Safety Tests for Catering and Food Businesses
Analyzes the chemicals remaining on the surface after disinfectant.
Test and Process Control Kits for Textile Finishing and Dyeing Mills
Monitors cationic surfactant/QAC residues, helping evaluate staining and incompatibility risks from softeners, fixatives, disinfectants or cationic chemical carryover.